The Omron CP2E Series Micro PLC Modules, specifically the CP2E-E40DR-A and CP2E-E60DR-A, are engineered for demanding machine control and process automation. These units combine a reliable relay output stage with a powerful AC power supply, ensuring stable operation in harsh industrial conditions. With 40 I/O points (24 inputs, 16 outputs) for the E40DR-A and 60 I/O points (36 inputs, 24 outputs) for the E60DR-A, they offer scalable solutions for applications ranging from packaging lines to conveyor systems. The CP2E family is known for its robust construction, wide temperature tolerance (-20 to 60°C), and compliance with international standards, making it a trusted choice for OEMs and system integrators worldwide.
| Specification | AC Power Supply (CP2E-E40DR-A / CP2E-E60DR-A) | DC Power Supply (CP2E-E40DR-D / CP2E-E60DR-D) |
|---|---|---|
| Model | CP2E-Standard D@-A | CP2E-Standard D@-D |
| Enclosure | Mounted in a panel | |
| Dimensions (H × D × W) | CPU Unit with 40 I/O points (CP2E-@40D@-@): 90mm *1 × 80mm *2 × 150mm CPU Unit with 60 I/O points (CP2E-@60D@-@): 90mm *1 × 80mm *2 × 195mm |
|
| Weight | CPU Unit with 40 I/O points (CP2E-@40D@-@): 640g max. CPU Unit with 60 I/O points (CP2E-@60D@-@): 780g max. |
|
| Supply voltage | 100 to 240 VAC 50/60 Hz | 24 VDC |
| Operating voltage range | 85 to 264 VAC | 20.4 to 26.4 VDC |
| Power consumption | 50 VA/100 VAC max. (CP2E-@30/40/60D@-A) 70 VA/240 VAC max. |
20W max. (CP2E-@30/40/60D@-D) *4 |
| Inrush current | 120 VAC, 20 A for 8 ms max. for cold start at room temperature 240 VAC, 40 A for 8 ms max. for cold start at room temperature |
24 VDC, 30A for 20 ms max. for cold start at room temperature |
| External power supply *3 | 24 VDC, 300 mA (CP2E-@30/40/60D@-A) | Not provided. |
| Insulation resistance | 20 MΩ min. (at 500 VDC) between the external AC terminals and GR terminals | Not isolated between primary and secondary DC power supplies |
| Dielectric strength | 2,300 VAC 50/60Hz for 1 min between AC external and GR terminals Leakage current: 5 mA max. |
Not isolated between primary and secondary DC power supplies |
| Power interrupt time | 10 ms min. | 2 ms min. |
| Ambient operating temperature | -20 to 60°C | |
| Ambient humidity | 10% to 90% | |
| Atmosphere | No corrosive gas. | |
| Ambient storage temperature | -20 to 75°C (excluding battery) | |
| Altitude | 2,000 m max. | |
| Pollution degree | 2 or less: Conforms to IEC61010-2-201. | |
| Noise resistance | 2 kV on power supply line (Conforms to IEC61000-4-4.) | |
| Overvoltage category | Category II: Conforms to IEC61010-2-201. | |
| EMC immunity level | Zone B | |
| Vibration resistance | Conforms to IEC60068-2-6.5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) |
|
| Shock resistance | Conforms to IEC60068-2-27.147 m/s2, 3 times in X, Y, and Z directions |