The Allen-Bradley 1791DS-IB8XOBV4 is a DeviceNet Safety CompactBlock input module designed for distributed safety I/O in industrial automation systems. This module combines 8 safety-rated digital inputs (sink/source configurable) with 4 solid-state safety outputs, enabling efficient machine safety control and monitoring. Its DeviceNet interface supports both standard and safety-specific communication protocols, allowing seamless integration into Rockwell Automation GuardLogix or other safety controllers. The 1791DS-IB8XOBV4 is ideal for applications requiring fast response times, high reliability, and compliance with global safety standards. Each input channel features dual-channel monitoring and pulse testing for fault detection, while outputs provide short-circuit and overload protection. The module’s compact form factor (approx. 120 x 80 x 60 mm) and pluggable terminal blocks simplify installation and maintenance. It operates over a wide temperature range (-20°C to +60°C) and is compatible with DeviceNet cables up to 500 meters (thick cable) or 100 meters (thin cable). For safety configuration, use RSNetWorx for DeviceNet or Studio 5000 software. Below are the detailed technical specifications:
| Parameter | Specification |
|---|---|
| Product Type | DeviceNet Safety CompactBlock I/O Module |
| Model | 1791DS-IB8XOBV4 |
| Number of Safety Inputs | 8 (dual-channel, configurable as sink/source) |
| Number of Safety Outputs | 4 (solid-state, source type, 0.5 A per output) |
| Input Voltage Range | 24 V DC (nominal), 19.2 – 30 V DC |
| Output Voltage Range | 24 V DC (nominal), 20.4 – 30 V DC |
| Output Current per Channel | 0.5 A (continuous), 2 A (peak, 10 ms) |
| Total Output Current | 2 A (all outputs simultaneously) |
| Safety Integrity Level | SIL 3 (IEC 61508), Category 4 (EN 954-1), PL e (ISO 13849-1) |
| Communication Protocol | DeviceNet (CIP Safety) |
| DeviceNet Data Rate | 125, 250, or 500 kbps (selectable) |
| DeviceNet Node Address | 0 – 63 (configurable via DIP switches) |
| Input Response Time | < 5 ms (typical) |
| Output Response Time | < 10 ms (typical) |
| Input Filter Time | 0.5 – 25 ms (programmable) |
| Fault Detection | Short-circuit, overload, open-wire, cross-channel fault |
| Indicators | Power, Network Status, Input/Output Status, Fault (LEDs) |
| Power Supply | 24 V DC (sensor and actuator power via DeviceNet or auxiliary) |
| Power Consumption | < 5 W (typical) |
| Isolation Voltage | 500 V DC (input to system, output to system) |
| Enclosure Rating | IP20 (NEMA 1) |
| Operating Temperature | -20°C to +60°C (-4°F to +140°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Humidity | 5% to 95% (non-condensing) |
| Vibration Resistance | 5 g Standard Models 10-500 Hz (per IEC 60068-2-6) |
| Shock Resistance | 30 g (11 ms half-sine, per IEC 60068-2-27) |
| Dimensions (H x W x D) | 120 mm x 80 mm x 60 mm (approx.) |
| Weight | Approx. 0.35 kg (0.77 lb) |
| Mounting | DIN rail (35 mm) or panel mount |
| Connector Type | Pluggable terminal blocks (screw-type, 12-pin for I/O, 5-pin for DeviceNet) |
| Wire Size | 0.2 – 2.5 mm² (AWG 24-14) for I/O; 0.14 – 1.5 mm² (AWG 26-16) for DeviceNet |
| Certifications | CE, cULus, TÜV, ATEX (Zone 2), IECEx (Zone 2) |
| Software Compatibility | RSNetWorx for DeviceNet, Studio 5000, RSLogix 5000 (v20+) |
| Safety Configuration | Via DeviceNet safety master (e.g., GuardLogix 1756-L7xS or 1769-L3xERMS) |
| Maximum Cable Length (DeviceNet) | 500 m (thick cable), 100 m (thin cable) Standard Models 125 kbps |
| Typical Applications | E-stop monitoring, light curtain interfaces, safety gate switches, two-hand control |
| Warranty | 2 years (standard) |