The OMRON CJ2H-CPU68 and CJ2H-CPU67 are flagship CPU units within the CJ-Series PLC family, engineered for demanding industrial automation tasks that require high-speed logic execution, extensive memory capacity, and robust system integration. These processors deliver exceptional performance with a minimum basic instruction time of just 0.016 µs, enabling precise control in high-speed machinery, packaging lines, and process automation. With user memory capacities ranging from 250K steps (CJ2H-CPU67) to 400K steps (CJ2H-CPU68), they support large-scale programs and complex data handling. The units feature a comprehensive I/O and memory architecture, including dedicated areas for synchronous data refresh, DeviceNet, and CPU Bus Units, ensuring seamless connectivity with OMRON’s extensive lineup of special I/O and network modules.
| Item | CJ2H-CPU67 | CJ2H-CPU68 |
|---|---|---|
| User Memory | 250K steps | 400K steps |
| I/O Bits | 2,560 bits (Normal Mode: 200 ms overhead; add 100 ms + transferred words × (0.33 ms or 0.87 ms) when using EtherNet/IP tag data links) | |
| Overhead Processing Time | Included in I/O refresh timing (see above) | |
| Execution Time | Basic Instructions: 0.016 µs min.; Special Instructions: 0.048 µs min. | |
| Interrupt Task Startup Time | 26 µs or 17 µs (with high-speed interrupt); Return to cyclic task: 11 µs or 8 µs | |
| Max. Connectable Units | 10 Units per CPU/Expansion Rack; 40 Units total per PLC | |
| Max. Expansion Racks | 3 | |
| I/O Area | 2,560 bits (160 words): CIO 0000 to CIO 0159 | |
| Link Area | 3,200 bits (200 words): CIO 1000 to CIO 1199 | |
| Synchronous Data Refresh Area | 1,536 bits (96 words): CIO 1200 to CIO 1295 | |
| CPU Bus Unit Area | 6,400 bits (400 words): CIO 1500 to CIO 1899 | |
| Special I/O Unit Area | 15,360 bits (960 words): CIO 2000 to CIO 2959 | |
| DeviceNet Area | 9,600 bits (600 words): CIO 3200 to CIO 3799; plus 3,200 bits (200 words): CIO 1300 to CIO 1499 | |
| Internal I/O Area | 37,504 bits (2,344 words): CIO 3800 to CIO 6143 (not for external I/O) | |
| Work Area | 8,192 bits (512 words): W000 to W511; plus 8,192 bits (512 words): H000 to H511 | |
| Holding Area | Bits maintain ON/OFF status across power cycles; H512 to H1535 reserved for function block instances | |
| Auxiliary Area | Read-only: 31,744 bits (1,984 words) – A0 to A447; Read/write: 16,384 bits (1,024 words) – A448 to A1471 | |
| Temporary Area | 16 bits: TR0 to TR15 | |
| Timer Area | 4,096 timer numbers (T0000 to T4095, separate from counters) | |
| Counter Area | 4,096 counter numbers (C0000 to C4095, separate from timers) | |
| DM Area | 32K words; Special I/O Units: D20000 to D29599; CPU Bus Units: D30000 to D31599 | |
| EM Area | 32K words/bank × 25 banks max. (E00_00000 to E18_32767); bits addressable; force-set/reset supported (unit version 1.2 or higher) | |
| Index Registers | IR0 to IR15 (for indirect addressing; can be task-specific or shared) | |
| Cyclic Task Flag Area | 128 flags | |
| Memory Card | 128 MB, 256 MB, or 512 MB (for program storage and data logging) | |
| Operating Modes | PROGRAM (preparation), MONITOR (online editing), RUN (normal execution) | |
| Execution Mode | Normal Mode |