Omron PLC CS-Series Process Analog I/O Unit CS1W-PTS56

Series#: Omron

Product Details

  • Omron CS1W-PTS56 – High-Precision 8-Channel Resistance Thermometer Input Unit for CS-series PLCs.
  • Supports Pt100 and JPt100 sensors with 3-wire connection for accurate temperature measurement.
  • ±0.3% of PV accuracy at 25°C ensures reliable process control in industrial environments.
  • Fast 250 ms conversion time across all 8 inputs with 10-minute warmup stabilization.
  • Easy integration into CS-series CPU or Expansion Racks with 10-word CIO allocation per unit.
  • Robust DM area configuration for sensor type, range, and alarm settings without external tools.
  • 100% Genuine and New, rigorously inspected before international dispatch.

Specification

The Omron CS1W-PTS56 is a dedicated Process Analog I/O Unit within the CS-series platform, engineered for precise resistance thermometer input acquisition. With 8 independent channels supporting Pt100 and JPt100 sensors, this unit delivers industrial-grade accuracy (±0.3% of PV) and rapid 250 ms conversion across all inputs. Designed for seamless mounting on CS-series CPU or Expansion Racks, the CS1W-PTS56 stores process data in hexadecimal or BCD format within the CIO Area, while the DM Area allows flexible configuration of sensor type, input range, and process value alarms. Its 3-wire connection minimizes conductor resistance influence (0.4°C/Ω max), ensuring stable readings even in long cable runs. Ideal for temperature-critical processes, this unit is 100% original and new, ready for prompt delivery.

Parameter Specification
Model CS1W-PTS56
Applicable PLC CS Series
Unit Type CS-series Special I/O Unit
Mounting Position CS-series CPU Rack or Expansion Rack (Not for C200H Expansion I/O Rack or SYSMAC BUS Remote I/O Slave Rack)
Unit Numbers 00 to 95 (No duplicates allowed); 10 words/Unit
Number of Temperature Sensor Inputs 8; Pt100 (JIS, IEC), JPt100; Same sensor type and range for all inputs
Data Storage in CIO Area Actual process data stored as 4-digit hexadecimal (binary or BCD) in allocated words
Accuracy (25°C) ±0.3% of PV or ±0.8°C (±1.6°F), whichever is greater, ±1 digit max
Temperature Characteristics Per platinum resistance thermometer type (3-wire method)
Influence of Conductor Resistance 0.4°C/Ω max; 0.5 mA
Warmup Time 10 min
Conversion Time 250 ms/8 inputs
Maximum Time to Store Data in CPU Unit Conversion period + one CPU Unit cycle
  • DM Area Allocation: 100 words/Unit for CPU-to-unit settings including sensor type, input range, zero/span adjustment, and alarm thresholds (L, H).
  • Process Value Alarm: Additional 1 word/Unit dedicated to alarm output from CPU to unit for process value monitoring.
  • Sensor Error Detection: Built-in diagnostics for sensor errors, conversion data enabled flag, and process value alarms (L, H) communicated to CPU.
  • Scaling Flexibility: All inputs support unified scaling to industrial units, simplifying system calibration and maintenance.
  • Industrial Durability: Designed for continuous operation in harsh environments, with robust isolation and noise immunity per CS-series standards.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp