Mitsubishi AJ65SBTB2N-8S CC-Link PLC Module

Series#: Mitsubishi

Product Details

  • Part Number: AJ65SBTB2N-8S and AJ65SBTB2N-16S – High-reliability AC output modules for Mitsubishi CC-Link systems.
  • 8-point (AJ65SBTB2N-8S) and 16-point (AJ65SBTB2N-16S) AC output configurations, rated for 100–240 VAC loads.
  • Robust photocoupler isolation ensures safe and noise-immune signal transmission.
  • Supports high inrush currents up to 25 A for 10 ms, ideal for driving inductive loads like relays and solenoids.
  • Built-in CR surge absorber for superior protection against voltage transients.
  • Compact, lightweight design (0.25 kg for 8-point, 0.35 kg for 16-point) for easy DIN-rail mounting.
  • 100% Genuine and New, rigorously inspected before international dispatch.

Specification

The AJ65SBTB2N-8S and AJ65SBTB2N-16S are Mitsubishi CC-Link remote I/O modules engineered for demanding AC output applications. These modules provide reliable switching of 100–240 VAC loads with photocoupler isolation, ensuring galvanic separation between the CC-Link network and field devices. With a maximum load current of 0.6 A per point and robust surge suppression, they are ideally suited for controlling contactors, valves, and lighting systems in industrial automation. The modules occupy a single station with 32-point assignment, simplifying network configuration. Below are the comprehensive technical specifications.

Parameter AJ65SBTB2N-8S AJ65SBTB2N-16S
Number of Output Points 8 points 16 points
Insulation Method Photocoupler Photocoupler
Rated Load Voltage 100 to 240 V AC 50/60 Hz ±5% 100 to 240 V AC 50/60 Hz ±5%
Max. Load Voltage 264 V AC 264 V AC
Max. Load Current 0.6 A/point, 2.4 A/1 common 0.6 A/point, 4.8 A/1 common
Min. Load Voltage × Current 50 V AC 100 mA, 100 V AC 10 mA, 240 V AC 10 mA 50 V AC 100 mA, 100 V AC 10 mA, 240 V AC 10 mA
Max. Inrush Current 25 A 10 ms or lower 25 A 10 ms or lower
Leakage Current at OFF 1.5 mA rms or lower (100 V AC rms 60 Hz), 3 mA rms or lower (200 V AC rms 60 Hz) 1.5 mA rms or lower (100 V AC rms 60 Hz), 3 mA rms or lower (200 V AC rms 60 Hz)
Max. Voltage Drop at ON 1.5 V rms or lower (at 0.6 A) 1.5 V rms or lower (at 0.6 A)
Surge Suppression C·R absorber (0.01 μF + 47 Ω) C·R absorber (0.01 μF + 47 Ω)
Common Method 8 points/1 common (terminal block 2-wire type) 16 points/1 common (terminal block 2-wire type)
Number of Stations Occupied 1 station, 32 points assignment (use 8 points) 1 station, 32 points assignment (use 16 points)
Noise Durability Simulator noise 1500 Vp-p, noise width 1 ms, carrier frequency 25 to 60 Hz; Fast transient/burst IEC61000-4-4: 1 kV Simulator noise 1500 Vp-p, noise width 1 ms, carrier frequency 25 to 60 Hz; Fast transient/burst IEC61000-4-4: 1 kV
Withstand Voltage 2830 V AC between all AC external terminals and ground, rms/3 cycles (2000 m above sea level); 500 V AC for 1 minute between all DC external terminals and ground 2830 V AC between all AC external terminals and ground, rms/3 cycles (2000 m above sea level); 500 V AC for 1 minute between all DC external terminals and ground
Insulation Resistance 10 MΩ or higher, measured with 500 V DC insulation tester between all AC/DC external terminals and ground 10 MΩ or higher, measured with 500 V DC insulation tester between all AC/DC external terminals and ground
Weight 0.25 kg (0.55 lb) 0.35 kg (0.77 lb)
External Connection Method 7-point 2-piece terminal block (transmission circuit, module power supply); Direct-type 18-point terminal block (I/O power supply area) (M3 screw) 7-point 2-piece terminal block (transmission circuit, module power supply); Direct-type 34-point terminal block (I/O power supply area) (M3 screw)
Applicable Solderless Terminal RAV1.25-3.5 (JIS C 2805) [Wire: 0.3–1.25 mm²]; V2-MS3, RAP2-3S, RAP2-3; 2-3N, 2-3S [Wire: 1.25–2 mm²] RAV1.25-3.5 (JIS C 2805) [Wire: 0.3–1.25 mm²]; V2-MS3, RAP2-3S, RAP2-3; 2-3N, 2-3S [Wire: 1.25–2 mm²]
  • CC-Link Compatibility: Both modules are fully compliant with the Mitsubishi CC-Link fieldbus standard, enabling seamless integration into existing automation networks.
  • Output Protection: Integrated C·R surge absorber protects against high-voltage transients, extending relay and load life.
  • Environmental Robustness: Withstands 2830 V AC dielectric strength and offers 10 MΩ insulation resistance, ensuring reliable operation in harsh industrial environments.
  • Terminal Flexibility: Dual terminal blocks separate transmission/power circuits from I/O wiring, simplifying installation and troubleshooting.
  • Compact Footprint: The slim profile (0.25–0.35 kg) allows high-density mounting on DIN rails, saving cabinet space.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp