The Fluke 718 Pressure Calibrator is a versatile field instrument designed for process technicians and calibration engineers who demand precision and portability. This device integrates a high-accuracy pressure sensor, a built-in pneumatic pump, and a 24 mA loop measurement capability, making it ideal for calibrating pressure transmitters, transducers, and switches. The Fluke 718 supports multiple pressure ranges through its internal gauge models (1G, 30G, 100G, 300G) and can be further expanded using the extensive 700 Series Pressure Modules, covering from 0–1 inH₂O to 10,000 psi. With its intuitive interface, zero, min/max, hold, and damp functions, and compliance with CSA and EMC standards, the Fluke 718 ensures reliable performance in harsh industrial environments. Below are the detailed technical specifications.
| Technical Specifications | |
|---|---|
| Fluke 718 Series | |
| Measure pressure | (Internal sensor) |
| Accuracy | 0.025% full scale |
| Functions | Zero, min/max, hold, damp |
| Fluke 718 1G | |
| Range | -1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa) |
| Resolution | 0.0001 psi, 0.001 mbar, 0.0001 kPa |
| Over pressure | 5x Full Scale |
| Functions | Zero, Min, Max, Hold, Damp |
| Fluke 718 30G | |
| Range | -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa) |
| Resolution | 0.001 psi, 0.1 mbar, 0.01 kPa |
| Over pressure | 5x Full Scale |
| Functions | Zero, Min, Max, Hold, Damp |
| Fluke 718 100G | |
| Range | -12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa) |
| Resolution | 0.01 psi, 0.1 mbar, 0.01 kPa |
| Over pressure | 2x Full Scale |
| Functions | Zero, Min, Max, Hold, Damp |
| Fluke 718 300G | |
| Range | -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa) |
| Resolution | 0.01 psi, 1 mbar, 0.1 kPa |
| Over pressure | 375 psi / 25 bar |
| Functions | Zero, Min, Max, Hold, Damp |
| Fluke 718 series via 700 Series Pressure Modules | |
| Range | 29 pressure modules, 0 – 1 inH₂O to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs |
| Resolution | Per pressure module specs |
| Accuracy | To 0.025% of full span, per pressure module specs |
| Functions | Zero, Min, Max, Hold, Damp |
| Fluke 718 Series Via Built in Pump | |
| Range | -12 psi or -850 mbar to full scale. Supported Pressure Units: psi, inH₂O (4°C), inH₂O (20°C), cmH₂O (4°C), cmH₂O (20°C), bar, mbar, kPa, inHg, mmHg, kg/cm² |
| Loop power range | 24 V DC |
| Accuracy | ±10% |
| mA Measure | |
| Range | 0 mA to 24 mA |
| Resolution | 0.001 mA |
| Accuracy | 0.015% + 1 count |
| General Specifications | |
| Maximum voltage | 30 volts (non-operating) |
| Temperature | -40°C to 60°C |
| Operating temperature | -10°C to 55°C |
| Relative humidity | 95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C) |
| Operating altitude | 3,000 M max |
| Shock | 1 M drop test |
| Vibration | Random, 2 g, 5 Hz – 500 Hz |
| Safety | CSA C22.2 No. 1010.1: 1992 |
| EMC | EN50082-1: 1992 and EN55022: 1994 Class B |
| Size | 216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in) |
| Weight | 992 g (35 oz) |
| Power, battery life | 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 |
| Battery life | 4 to 20 hours typical, depending on functions used |
| Warranty | Three years (one year on pressure pump in Fluke 718) |
| Display | LCD, 5 digit pressure and current simultaneous |