The Fluke 87V MAX True-RMS Digital Multimeter is engineered for the most demanding industrial, electrical, and HVAC applications. It combines the legendary accuracy of the 87V series with extreme ruggedness—IP67 waterproof and dustproof rating, plus a 4-meter drop survival. This meter delivers true-RMS measurements on distorted waveforms, a 20 kHz bandwidth with low-pass filter for variable frequency drives (VFDs), and a wide temperature range from -200°C to +1090°C. Whether you are troubleshooting motor drives, high-energy switchgear, or sensitive electronics, the Fluke 87V MAX provides the precision, safety, and durability you can rely on in the field.
| Electrical Specifications | ||
|---|---|---|
| DC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±(0.05% + 1) | |
| Maximum Resolution | 0.1 mV | |
| AC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±(0.7% + 4) true-rms | |
| AC Bandwidth | 20 kHz with low pass filter; 3 dB Standard Models 1 kHz | |
| Maximum Resolution | 0.1 mV | |
| DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds max) |
| Accuracy | ±(0.2% + 2) | |
| Maximum Resolution | 0.1 μA | |
| AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds max) |
| Accuracy | ±(1.0% + 2) true-rms | |
| Maximum Resolution | 0.1 μA | |
| Resistance | Range | 0.1 Ω to 50 MΩ |
| Accuracy | ±(0.2% + 1) | |
| Maximum Resolution | 0.1 Ω | |
| Capacitance | Range | 0.01 nF to 9999 μF |
| Accuracy | ±(1% + 2) | |
| Maximum Resolution | 0.01 nF | |
| Frequency | Range | 0.5 Hz to 199.99 kHz |
| Accuracy | ±(0.005% + 1) | |
| Maximum Resolution | 0.01 Hz | |
| Duty Cycle | Maximum Duty Cycle | 99.9% |
| Accuracy | ±(0.2% per kHz + 0.1%) | |
| Maximum Resolution | 0.1% | |
| Temperature Measurement | –200.0 °C to 1090 °C / –328.0 °F to 1994.0 °F (excluding probe) | |
| 80 BK Temperature Probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater; –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater | |
| Conductance | Maximum Conductance | 60.00 nS |
| Accuracy | ±(1.0% + 10) | |
| Maximum Resolution | 0.01 nS | |
| Diode Test | Range | 2 V |
| Resolution | 0.001 V | |
| Accuracy | ±(1% + 1) | |
| Diagnostics & Data Storage | Peak Min/Max | 250 μS |
| Min/Max/Avg | Yes | |
| Reading Hold / Auto (Touch) Hold | Yes | |
| Relative Reference | Yes | |
| Display | Digital | 6000 counts updates 4/second; 19,999 counts in high–resolution mode |
| Analog Bar Graph | 32 segments, updates 40/second | |
| Backlight | Two level | |
| Low Pass Filter (VFD Measurements) | Yes | |
| Input Alert™ | Yes | |
| Safety Specifications | ||
| Safety Rating | IEC61010-1: Pollution Degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V | |
| Agency Approvals | CE, CSA | |
| Mechanical & General Specifications | ||
| IP Rating | IEC 60529: IP67 | |
| Power | Three AA batteries. 800 hours typical, without backlight | |
| Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
| Weight | 698.5 g (with holster) | |
| Warranty | Limited lifetime | |
| Environmental Specifications | ||
| Operating Temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
| Storage Temperature | -40 °C to + 60 °C | |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C); 0% – 70% (35 °C – 55 °C) | |
| Operating Altitude | 2000 m |
What Does Our Clients Say
Mitsubishi MR-J4
Laura Navas
Great product!
2019/12/01
Keyence sensor
EQDR SALES
Original and fast!
2020/02/22