The Fluke 715 Volt/mA Loop Calibrator is a precision, handheld instrument engineered for industrial process technicians and control system engineers who demand reliable and accurate loop calibration. Designed to measure, source, and simulate mV, V, and mA signals, the Fluke 715 simplifies troubleshooting of 4-20 mA loops, transmitter outputs, and PLC inputs. With a robust build that withstands harsh field conditions—including a 1 m drop test and random vibration up to 2 G—this calibrator ensures consistent performance in temperatures from -10°C to 55°C. Its intuitive interface and 5-digit LCD provide clear readings, while the integrated 24 V DC loop power eliminates the need for external power supplies during testing. Whether you're commissioning new loops or maintaining existing systems, the Fluke 715 delivers the accuracy and versatility required for efficient plant operations.
| Parameter | Specification | Details |
|---|---|---|
| Measure / Source mV | Range | 0 to 200 mV |
| - | Resolution | 0.01 mV |
| - | Accuracy | 0.015% + 2 counts |
| Measure / Source V | Range | 0 to 20 V |
| - | Resolution | 0.001 V |
| - | Accuracy | 0.01% + 2 counts |
| Measure / Source / Simulate mA (% of span) | Range | 0 to 24 mA (-25% to 125%) |
| - | Resolution | 0.001 mA |
| - | Accuracy | 0.01% + 2 counts |
| - | Sink (simulate transmitter) | Display mA or % of span |
| Loop Power | Range | 24 V DC |
| - | Accuracy | ±10% |
| - | Drive | 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V |
| Display | Clear 5-digit LCD | |
| Operating Temperature | -10°C to 55°C | |
| Storage Temperature | -40°C to 60°C | |
| Humidity (without condensation) | 95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C) | |
| Operating Altitude | 3,000 m max | |
| Safety | CSA C22.2 No. 1010.1:1992 | |
| Size (L x W x D) | 187 x 87 x 32 mm (7.93 x 3.86 x 2.06 in) | |
| Weight | Approx. 330 g (21 oz) | |
| Warranty | 3 years | |
| Shock and Vibration | Random, 2 G, 5-500 Hz; 1 m drop test | |
| Battery Type | Single 9 V battery, ANSI/NEDA 1604A or IEC 6LR619V alkaline |